Fehlersuche Ratgeber Trennmittel

Release agent residue and streaks on the panel: how to find the cause

Streaks or a film on dark or textured decors? It is rarely the fluid itself – usually nozzle position, spray pattern or worn buffing wheels. Here is how to proceed.

Release agent residue and streaks on the panel: how to find the cause

If streaks or a fine film appear on the panel surface after the edge banding machine – especially on dark or textured decors – the cause is rarely the release agent itself. In practice it is almost always setup and wear.

The most common causes

  • Wrong nozzle projection or angle: the fluid does not only reach the edge area but spreads onto the surface.
  • Too much fluid: more release agent does not work better – it leaves residue.
  • Worn or saturated buffing wheels: they spread fluid and glue residue over the panel instead of absorbing them.
  • Parts pushed across a wetted surface – e.g. on return conveyors.

Step by step to the cause

  1. Switch off the buffing unit for a test and check the pure spray pattern on the panel.
  2. Check and correct nozzle projection and alignment with the nozzle gauge.
  3. Reduce the spray quantity until the edge areas are just evenly wetted.
  4. Check the buffing wheels and replace them if necessary. For double-motor units, a cloth-sisal flap wheel followed by a cloth polishing ring has proven itself.

Set up correctly, no disturbing residue remains on the panel.

Questions about your line? Send us a photo or video – we will help you choose and set up the right fluid.

Request advice

Read more: Which fluid at which position?