{"product_id":"ultra-thin-duese","title":"Ultra-Thin nozzle","description":"\u003cp\u003eThe \u003cstrong\u003eUltra-Thin nozzle\u003c\/strong\u003e has been developed for solvent-free (VOC-free) agents such as \u003ca href=\"\/en\/products\/irelease\"\u003eiRelease\u003c\/a\u003e and \u003ca href=\"\/en\/products\/iclean\"\u003eiClean\u003c\/a\u003e. It atomises extremely finely and without overspray – with low air and liquid consumption.\u003c\/p\u003e\u003ch2\u003eBenefits\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eFinest atomisation without overspray – very economical\u003c\/li\u003e\u003cli\u003eHaptic feedback – adjustable in small, audible and tactile steps\u003c\/li\u003e\u003cli\u003eVarious lances for precise application in any position\u003c\/li\u003e\u003cli\u003eEasy to operate\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eApplication area\u003c\/h2\u003e\u003cp\u003eThe Ultra-Thin nozzle is operated exclusively with the \u003ca href=\"\/en\/products\/clou%C2%AE\"\u003eCLOU®\u003c\/a\u003e. Solvent-free agents should only be applied via this nozzle – conventional nozzles apply too much liquid.\u003c\/p\u003e\u003cp class=\"lcm-hint\"\u003eSpare and wear parts for the Ultra-Thin nozzle are charged separately.\u003c\/p\u003e\n\u003cdiv class=\"lcm-video\"\u003e\u003ciframe src=\"https:\/\/www.youtube-nocookie.com\/embed\/quAiThO3Ty0\" title=\"Video\" loading=\"lazy\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\u003cdiv class=\"lcm-faq\"\u003e\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\u003cdetails\u003e\u003csummary\u003eWhat is the Ultra-Thin nozzle for?\u003c\/summary\u003e\u003cp\u003eFor ultra-thin application amounts. It is supplied via the CLOU® pressure tank and is the approved nozzle for the solvent-free system with iRelease and iClean.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eHow do I set the nozzle correctly?\u003c\/summary\u003e\u003cp\u003eThe starting setting as per data sheet is 17 clicks at min. 5 bar. Set distance and angle with the Ultra-Thin nozzle gauge, then fine-tune each position.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWhat do I need to note when replacing the nozzle?\u003c\/summary\u003e\u003cp\u003eRelease the pressure at the CLOU® first – simply open the CLOU® cap. Then disconnect air and fluid hose as usual, loosen the M10 nut, fit the new nozzle and align it with the Ultra-Thin nozzle gauge.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eThe spray pattern is uneven – what should I do?\u003c\/summary\u003e\u003cp\u003eCommon causes are air in the fluid line, a dirty or clogged nozzle or a misaligned nozzle. Check lines and connections, clean the nozzle and realign it with the nozzle gauge. Use approved LcM® fluids only – unsuitable fluids can clog nozzles. If that does not help, our service team will support you.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eIs there a guarantee?\u003c\/summary\u003e\u003cp\u003eWhen LcM® fluids are used exclusively, we give a lifetime guarantee on our spray systems. Spare and wear parts for the Ultra-Thin nozzle and CLOU® are excluded.\u003c\/p\u003e\u003c\/details\u003e\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the Ultra-Thin nozzle for?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For ultra-thin application amounts. It is supplied via the CLOU® pressure tank and is the approved nozzle for the solvent-free system with iRelease and iClean.\"}},{\"@type\":\"Question\",\"name\":\"How do I set the nozzle correctly?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The starting setting as per data sheet is 17 clicks at min. 5 bar. Set distance and angle with the Ultra-Thin nozzle gauge, then fine-tune each position.\"}},{\"@type\":\"Question\",\"name\":\"What do I need to note when replacing the nozzle?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Release the pressure at the CLOU® first – simply open the CLOU® cap. Then disconnect air and fluid hose as usual, loosen the M10 nut, fit the new nozzle and align it with the Ultra-Thin nozzle gauge.\"}},{\"@type\":\"Question\",\"name\":\"The spray pattern is uneven – what should I do?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Common causes are air in the fluid line, a dirty or clogged nozzle or a misaligned nozzle. Check lines and connections, clean the nozzle and realign it with the nozzle gauge. Use approved LcM® fluids only – unsuitable fluids can clog nozzles. If that does not help, our service team will support you.\"}},{\"@type\":\"Question\",\"name\":\"Is there a guarantee?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"When LcM® fluids are used exclusively, we give a lifetime guarantee on our spray systems. Spare and wear parts for the Ultra-Thin nozzle and CLOU® are excluded.\"}}]}\u003c\/script\u003e","brand":"LcM GmbH","offers":[{"title":"Standard (thread M10×1)","offer_id":54991169257795,"sku":"HSL-000255 - S","price":250.0,"currency_code":"EUR","in_stock":true},{"title":"with lance L=30 mm, 90°","offer_id":54991169290563,"sku":"HSL-000255","price":277.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0908\/1608\/6339\/files\/ultra-thin_nozzle_d469fc49-fd03-4d29-80cf-a7a0c58cffcf.jpg?v=1793317113","url":"https:\/\/www.lcm-gmbh.eu\/en\/products\/ultra-thin-nozzle","provider":"LcM GmbH","version":"1.0","type":"link"}